Design of Soft–Rigid Devices for Rehabilitative and Assistive Robotics
This book describes a comprehensive research project in which different devices for rehabilitation, assistance, and haptic applications are designed and developed. The fil-rouge is the user-centered perspective, that has been employed in all the design and development phases, and the exploitation of...
Պահպանված է:
| Հիմնական հեղինակ: | |
|---|---|
| Համատեղ հեղինակ: | |
| Ձևաչափ: | Էլեկտրոնային էլ․ գիրք |
| Լեզու: | անգլերեն |
| Հրապարակվել է: |
Cham :
Springer Nature Switzerland : Imprint: Springer,
2025.
|
| Հրատարակություն: | 1st ed. 2025. |
| Շարք: | Springer Theses, Recognizing Outstanding Ph.D. Research,
|
| Խորագրեր: | |
| Առցանց հասանելիություն: | https://doi.org/10.1007/978-3-031-84823-0 |
| Ցուցիչներ: |
Ավելացրեք ցուցիչ
Չկան պիտակներ, Եղեք առաջինը, ով նշում է այս գրառումը!
|
MARC
| LEADER | 00000nam a22000005i 4500 | ||
|---|---|---|---|
| 001 | 978-3-031-84823-0 | ||
| 003 | DE-He213 | ||
| 005 | 20260810155904.0 | ||
| 007 | cr nn 008mamaa | ||
| 008 | 250417s2025 sz | o |||| 0|eng d | ||
| 020 | |a 9783031848230 |9 978-3-031-84823-0 | ||
| 024 | 7 | |a 10.1007/978-3-031-84823-0 |2 doi | |
| 050 | 4 | |a R856-857 | |
| 072 | 7 | |a MQW |2 bicssc | |
| 072 | 7 | |a TEC059000 |2 bisacsh | |
| 072 | 7 | |a MQW |2 thema | |
| 082 | 0 | 4 | |a 610.28 |2 23 |
| 100 | 1 | |a Dragusanu, Mihai. |e author. |0 (orcid)0000-0001-9373-6866 |1 https://orcid.org/0000-0001-9373-6866 |4 aut |4 http://id.loc.gov/vocabulary/relators/aut | |
| 245 | 1 | 0 | |a Design of Soft–Rigid Devices for Rehabilitative and Assistive Robotics |h [electronic resource] / |c by Mihai Dragusanu. |
| 250 | |a 1st ed. 2025. | ||
| 264 | 1 | |a Cham : |b Springer Nature Switzerland : |b Imprint: Springer, |c 2025. | |
| 300 | |a 1 online resource (XX, 213 p. 141 illus.). |b 135 illus. in color. | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 341 | 0 | |b Table of contents navigation |2 onix | |
| 341 | 0 | |b Single logical reading order |2 onix | |
| 341 | 0 | |b Short alternative textual descriptions |2 onix | |
| 341 | 0 | |b Use of color is not sole means of conveying information |2 onix | |
| 341 | 0 | |b Use of high contrast between text and background color |2 onix | |
| 341 | 0 | |b Next / Previous structural navigation |2 onix | |
| 341 | 0 | |b All non-decorative content supports reading without sight |2 onix | |
| 347 | |a text file |b PDF |2 rda | ||
| 490 | 1 | |a Springer Theses, Recognizing Outstanding Ph.D. Research, |x 2190-5061 | |
| 505 | 0 | |a -- 1 Introduction -- 2 Hand/Wrist Exoskeleton -- 3 Design of Haptic Devices for Rehabilitive/Assistive Applications -- 4 Assistive Robotic Gripper Devices -- 5 Conclusions. | |
| 520 | |a This book describes a comprehensive research project in which different devices for rehabilitation, assistance, and haptic applications are designed and developed. The fil-rouge is the user-centered perspective, that has been employed in all the design and development phases, and the exploitation of soft robotics solutions allowing for a safe and comfortable interaction with the user. Extensive information concerning the design, the practical application and the assessment of various assistive devices for upper limb are included throughout the book, which also offers an up-to-date reference guide for dealing with future interdisciplinary research projects involving soft robotics and user-centered perspectives for enhancing robotic assistance capabilities. | ||
| 532 | 8 | |a Accessibility summary: This PDF does not fully comply with PDF/UA standards, but does feature limited screen reader support, described non-text content (images, graphs), bookmarks for easy navigation and searchable, selectable text. Users of assistive technologies may experience difficulty navigating or interpreting content in this document. We recognize the importance of accessibility, and we welcome queries about accessibility for any of our products. If you have a question or an access need, please get in touch with us at accessibilitysupport@springernature.com. | |
| 532 | 8 | |a No reading system accessibility options actively disabled | |
| 532 | 8 | |a Publisher contact for further accessibility information: accessibilitysupport@springernature.com | |
| 588 | |a Print version record. | ||
| 650 | 0 | |a Biomedical engineering. | |
| 650 | 0 | |a Control engineering. | |
| 650 | 0 | |a Robotics. | |
| 650 | 0 | |a Automation. | |
| 650 | 0 | |a User interfaces (Computer systems). | |
| 650 | 0 | |a Human-computer interaction. | |
| 650 | 1 | 4 | |a Biomedical Devices and Instrumentation. |
| 650 | 2 | 4 | |a Control, Robotics, Automation. |
| 650 | 2 | 4 | |a User Interfaces and Human Computer Interaction. |
| 710 | 2 | |a SpringerLink (Online service) | |
| 773 | 0 | |t Springer Nature eBook | |
| 776 | 0 | 8 | |i Printed edition: |z 9783031848223 |
| 776 | 0 | 8 | |i Printed edition: |z 9783031848247 |
| 776 | 0 | 8 | |i Printed edition: |z 9783031848254 |
| 830 | 0 | |a Springer Theses, Recognizing Outstanding Ph.D. Research, |x 2190-5061 | |
| 856 | 4 | 0 | |u https://doi.org/10.1007/978-3-031-84823-0 |
| 912 | |a ZDB-2-ENG | ||
| 912 | |a ZDB-2-SXE | ||
| 912 | |a ZDB-2-228 | ||
| 950 | |a Engineering (SpringerNature-11647) | ||
| 950 | |a Engineering (R0) (SpringerNature-43712) | ||
| 950 | |a Focus Bundle Clinical Medicine (SpringerNature-85398) | ||