Rehabilitation of metallic structural systems using fiber reinforced polymer (FRP) composites /
Saved in:
| Andre forfattere: | |
|---|---|
| Format: | Electronisk eBog |
| Sprog: | engelsk |
| Udgivet: |
Oxford :
Woodhead Publishing,
2024.
|
| Udgivelse: | Second edition. |
| Serier: | Woodhead Publishing Series in Civil and Structural Engineering Series.
|
| Fag: | |
| Online adgang: | ScienceDirect |
| Tags: |
Tilføj Tag
Ingen Tags, Vær først til at tagge denne postø!
|
MARC
| LEADER | 00000cam a2200000 i 4500 | ||
|---|---|---|---|
| 001 | on1463024441 | ||
| 003 | OCoLC | ||
| 005 | 20260915095235.0 | ||
| 006 | m o d | | ||
| 007 | cr ||||||||||| | ||
| 008 | 240906s2024 enk fo 000 0 eng d | ||
| 040 | |a UKAHL |b eng |e rda |c UKAHL |d OPELS |d OCLCO |d OCLCQ |d UKMGB |d OCLCL |d N$T |d EBLCP |d UKKRT |d OCLCF |d OCLCO | ||
| 015 | |a GBC4B4167 |2 bnb | ||
| 016 | 7 | |a 300295629 |2 Uk | |
| 019 | |a 1456758569 |a 1480966894 |a 1528577731 | ||
| 020 | |a 0443220832 |q (e-book) | ||
| 020 | |a 9780443220838 |q (electronic bk.) | ||
| 020 | |z 9780443220845 |q (pbk) | ||
| 024 | 8 | |a CIPO000135131 | |
| 035 | |a (OCoLC)1463024441 |z (OCoLC)1456758569 |z (OCoLC)1480966894 |z (OCoLC)1528577731 | ||
| 050 | 4 | |a TA418.9.C6 | |
| 082 | 0 | 4 | |a 620.1/18 |2 23/eng/20241113 |1 https://id.oclc.org/worldcat/ddc/E49TCJtwFGqycTY4MhR4VdgWCC |
| 245 | 0 | 0 | |a Rehabilitation of metallic structural systems using fiber reinforced polymer (FRP) composites / |c edited by Vistasp M. Karbhari. |
| 250 | |a Second edition. | ||
| 264 | 1 | |a Oxford : |b Woodhead Publishing, |c 2024. | |
| 300 | |a 1 online resource | ||
| 336 | |a text |b txt |2 rdacontent | ||
| 337 | |a computer |b c |2 rdamedia | ||
| 338 | |a online resource |b cr |2 rdacarrier | ||
| 490 | 1 | |a Woodhead Publishing Series in Civil and Structural Engineering Series | |
| 505 | 0 | |a Front Cover -- Rehabilitation of Metallic Structural Systems Using Fiber Reinforced Polymer (FRP) Composites -- Rehabilitation of Metallic Structural Systems Using Fiber Reinforced Polymer (FRP) CompositesWoodhead Publishing Series in ... -- Copyright -- Contents -- List of contributors -- Preface-Use of FRP for rehabilitation of metallic infrastructure -- References -- I -- Overview -- 1 -- Materials and systems level overview -- 1.1 Introduction -- 1.2 Overall considerations -- 1.3 Understanding adhesive bonds -- 1.4 Bond level considerations -- 1.5 Summary and conclusion | |
| 505 | 8 | |a 2 -- Environmental durability of adhesively bonded FRP/steel joints in bridge applications -- 2.1 Background -- 2.2 Predictive durability-modeling approaches -- 2.2.1 Mechanistic models -- 2.2.2 Non-mechanistic models -- 2.2.3 Correlation factors -- 2.2.4 Extrapolation of accelerated test data -- 2.2.5 Summary -- 2.3 Environmental aging of bonded FRP/steel joints -- 2.3.1 Introduction -- 2.3.2 Moisture -- Mechanisms of moisture ingress -- Effects of moisture on epoxy adhesives and FRP composites -- Effects of moisture on interfacial adhesion -- 2.3.3 Temperature -- 2.3.4 Research needs | |
| 505 | 8 | |a 2.4 Design and failure prediction of bonded joints in connection to environmental aging -- 2.4.1 Failure in FRP/steel adhesive joints -- 2.4.2 Cohesive zone modeling -- Fracture process zone -- J-integral -- 2.4.3 Characterization of cohesive laws -- 2.4.4 Summary -- 2.5 Multiphysics simulation to assess bonded joint durability -- 2.5.1 Material characterization -- 2.5.2 Finite element modeling -- 2.5.3 Dependency of cohesive laws on environmental factors -- 2.5.4 Effect of cyclic exposure on behavior of adhesive joints -- 2.6 Conclusions and remarks -- 2.6.1 General conclusions | |
| 505 | 8 | |a 2.6.2 Suggestions for future research -- Naturally aged specimens -- Cohesive laws -- Interlaminar properties of FRP composites -- Load effects -- References -- 3 -- Durability of steel components strengthened with fiber-reinforced polymer (FRP) composites -- 3.1 Introduction -- 3.2 Basic degradation mechanisms -- 3.3 Galvanic corrosion -- 3.3.1 Fundamental principles -- 3.3.2 Preventing galvanic corrosion -- 3.4 Degradation of the bulk adhesive -- 3.4.1 Susceptibility to moisture -- 3.4.2 Thermally-induced stresses and degradation -- 3.5 Degradation of the steel/adhesive interface | |
| 505 | 8 | |a 3.5.1 Surface chemistry -- 3.5.2 Organosilane adhesion promoters -- 3.6 Conclusions and future trends -- References -- 4 -- Effect of temperature on the bond behavior of CFRP-to-steel interface -- 4.1 Introduction -- 4.2 Effect of elevated temperatures -- 4.2.1 Effect of elevated temperatures on adhesive -- 4.2.2 Effect of elevated temperatures on the CFRP-to-steel interface -- Failure mode -- Mechanical behavior -- Bond-slip behavior -- Improvement of the temperature resistance -- Prediction of the residual bond strength -- 4.3 Temperature cycles | |
| 650 | 0 | |a Fibrous composites. | |
| 650 | 6 | |a Composites à fibres. |0 (CaQQLa)201-0024427 | |
| 650 | 7 | |a fibrous composite. |2 aat |0 (CStmoGRI)aat300189659 | |
| 650 | 7 | |a Fibrous composites |2 fast |0 (OCoLC)fst00923679 | |
| 700 | 1 | |a Karbhari, Vistasp M., |e editor. | |
| 776 | 0 | 8 | |i Print version: |z 9780443220845 |
| 776 | 0 | 8 | |i Print version: |a Karbhari, Vistasp M. |t Rehabilitation of Metallic Structural Systems Using Fiber Reinforced Polymer (FRP) Composites |d San Diego : Elsevier Science & Technology,c2024 |z 9780443220845 |
| 830 | 0 | |a Woodhead Publishing Series in Civil and Structural Engineering Series. | |
| 856 | 4 | 0 | |3 ScienceDirect |u https://www.sciencedirect.com/science/book/9780443220845 |